Fixes are available
8.0.0.6: WebSphere Application Server V8.0 Fix Pack 6
8.0.0.7: WebSphere Application Server V8.0 Fix Pack 7
8.0.0.8: WebSphere Application Server V8.0 Fix Pack 8
8.0.0.9: WebSphere Application Server V8.0 Fix Pack 9
8.0.0.10: WebSphere Application Server V8.0 Fix Pack 10
8.0.0.11: WebSphere Application Server V8.0 Fix Pack 11
8.0.0.12: WebSphere Application Server V8.0 Fix Pack 12
8.0.0.13: WebSphere Application Server V8.0 Fix Pack 13
8.0.0.14: WebSphere Application Server V8.0 Fix Pack 14
8.0.0.15: WebSphere Application Server V8.0 Fix Pack 15
APAR status
Closed as program error.
Error description
SIP sessions PMI counter shows the incorrect value
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM WebSphere Application * * Server V8.0 and V8.5 Session Initiation * * Protocol (SIP) Container * **************************************************************** * PROBLEM DESCRIPTION: SIP sessions Performance Monitoring * * Infrastructure (PMI) counter shows * * an incorrect value. * **************************************************************** * RECOMMENDATION: * **************************************************************** The internal counters of SIP sessions and SIP application sessions in the SessionsCounter object were not synchronized.
Problem conclusion
Added a synchronization mechanism to the internal counters. The fix for this APAR is currently targeted for inclusion in fix pack 8.0.0.7. Please refer to the Recommended Updates page for delivery information: http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
Temporary fix
Comments
APAR Information
APAR number
PM81225
Reported component name
WEBS APP SERV N
Reported component ID
5724H8800
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-01-23
Closed date
2013-01-24
Last modified date
2013-01-24
APAR is sysrouted FROM one or more of the following:
PM79304
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBS APP SERV N
Fixed component ID
5724H8800
Applicable component levels
R800 PSY
UP
R850 PSY
UP
Document Information
Modified date: