PM98768: USING CUSTOMDATASTOREHELPER, TESTCONNECTION OPERATION ON NETWORK DEPLOYMENT EDITION FAILS WITH EXCEPTION

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Using CustomDataStoreHelper, TestConnection operation on
    Network Deployment edition fails with the following
    exception:
    
    [9/27/13 6:01:31:233 GMT-12:00] 00000060 DataSourceCon E
    DSRA8040I:
    Failed to connect to the DataSource.  Encountered "":
    com.ibm.ws.exception.WsException: DSRA8050W: Unable to find the
    DataStoreHelper class specified: ExampleDataStoreHelper
    at java.net.URLClassLoader.findClass(URLClassLoader.java:434)
    at
    com.ibm.ws.bootstrap.ExtClassLoader.findClass(ExtClassLoader.jav
    a:204)
    at java.lang.ClassLoader.loadClassHelper(ClassLoader.java:699)
    at java.lang.ClassLoader.loadClass(ClassLoader.java:678)
    at
    com.ibm.ws.bootstrap.ExtClassLoader.loadClass(ExtClassLoader.jav
    a:119) Page 61 of 61
    at java.lang.ClassLoader.loadClass(ClassLoader.java:661)
    at
    com.ibm.ws.rsadapter.DSConfigHelper.loadClass(DSConfigHelper.jav
    a:1506)
    at
    com.ibm.ws.rsadapter.DSConfigHelper.createDataStoreHelper(DSConf
    igHelper.java:786)
    at
    com.ibm.ws.rsadapter.DSConfigurationHelper.testConnectionForGUI
    (DSConfigurationHelper.java:2164)
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All users of IBM WebSphere Application      *
    *                  Server V8.5 Network Deployment edition,     *
    *                  using the Test Connection operation         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Test Connection operation can fail      *
    *                      when datasource is configured with a    *
    *                      custom datastore helper on Network      *
    *                      Deployment edition                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The following exception might occur when performing a test
    connection operation on a datasource configured with a custom
    datastore helper on a Network Deployment edition.
    [9/27/13 6:01:31:233 GMT-12:00] 00000060 DataSourceCon E
    DSRA8040I: Failed to connect to the DataSource.  Encountered
    "":
    com.ibm.ws.exception.WsException: DSRA8050W: Unable to find the
    DataStoreHelper class specified: MyCustomDataStoreHelper
    

Problem conclusion

  • The WebSphere Relational Resource adapter code has been
    corrected to ensure that the custom datastore helper class is
    loaded and available for the Test Connection operation.
    
    The fix for this APAR is currently targeted for inclusion in
    fix pack 8.5.5.3.  Please refer to the Recommended Updates
    page for delivery information:
    http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM98768

  • Reported component name

    WAS LIBERTY COR

  • Reported component ID

    5725L2900

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-10-09

  • Closed date

    2014-06-27

  • Last modified date

    2017-04-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBS APP SERV N

  • Fixed component ID

    5724H8800

Applicable component levels

  • R850 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
28 April 2022