A fix is available
APAR status
-
Closed as program error.
Error description
-
Enhancement to PL/I run-time to handle a modified parameter being passed from Debug Tool.
Local fix
Problem summary
-
**************************************************************** * USERS AFFECTED: Users who try to debug a PL/I procedure * * that has more than 255 secondary entry * * points. * * * **************************************************************** * PROBLEM DESCRIPTION: An ABEND0C4 occurs in the Debug Tool * * module EQ00STO when a PL/I procedure * * contains more than 255 secondary * * entry points. * * * **************************************************************** * RECOMMENDATION: Apply the PTF for this APAR. * * * **************************************************************** The secondary entry point count field in the passed parameters overflows and returns an incorrect secondary entry point count to Debug Tool. This results in insufficient storage being allocated by Debug Tool which causes a storage overlay.
Problem conclusion
-
Increase the size of the field used to hold the secondary entry point count so that the count value returned to Debug tool is correct. The changes in this APAR require that the PTF for the corresponding Debug Tool APAR PI36219 is also applied to complete the fix.
Temporary fix
Comments
APAR Information
-
APAR number
PI36314
-
Reported component name
LE VA PL/I
-
Reported component ID
568819806
-
Reported release
780
-
Status
CLOSED PER
-
PE
NoPE
-
HIPER
NoHIPER
-
Special Attention
NoSpecatt / Xsystem
-
Submitted date
2015-03-04
-
Closed date
2015-05-04
-
Last modified date
2015-06-01
-
APAR is sysrouted FROM one or more of the following:
-
APAR is sysrouted TO one or more of the following:
106PC1Ÿ UI27323 UI27324
Modules/Macros
-
IBMPDDCU
Fix information
-
Fixed component name
LE VA PL/I
-
Fixed component ID
568819806
Applicable component levels
Fix is available
-
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"7.8"}]
Document Information
Modified date: