IBM Support

JR24042: CANNOT SET 'MANUAL' LOAD USING REPLICATION CENTER ON AIX

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When creating a Q subscription and choosing Manual load from the
    replication center on AIX, the ninth step (9.  Review Q
    Subscriptions) still shows 'None' instead of 'Manual' under the
    'Target Load' column.  The final SQL script that gets generated
    also shows 'N' for HAS_LOADPHASE in IBMQREP_SUBS table instead
    of 'E'.  DB2 ESE V8 fixpak 11 and DB2 Information Integrator
    Replication Edition are installed on this system.
    
    This problem doesn't happen when using replication center on
    Windows.
    

Local fix

Problem summary

  • AS DESCRIPED IN THE APAR
    

Problem conclusion

  • FIXED
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR24042

  • Reported component name

    WS II REPLICATI

  • Reported component ID

    5724C7415

  • Reported release

    820

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-05-26

  • Closed date

    2006-07-31

  • Last modified date

    2006-07-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WS II REPLICATI

  • Fixed component ID

    5724C7415

Applicable component levels

  • R820 PSY

       UP

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDP5R","label":"InfoSphere Replication Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"820"}]

Document Information

Modified date: