A fix is available
APAR status
Closed as program error.
Error description
0ABJ4031E Language table ABJRLN could not be dynamically loaded. when source code is in a sequential file
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: Users of CCCA who specify sequential input * * files. * **************************************************************** * PROBLEM DESCRIPTION: CCCA failed to handle sequential files * * because it skipped blank member name * **************************************************************** * RECOMMENDATION: * **************************************************************** When CCCA was given an input file that was not a PDS member, the generated job used a parameter list with a leading comma indicating an omitted member name, but this leading comma was being ignored, causing the parameters to be processed incorrectly. The main effect was that the DBCS option parameter was taken as the national language parameter, which caused it to attempt to load a non-existent module ABJRLN.
Problem conclusion
The parameter parsing logic for ABJTOKEN has been corrected to support a leading comma denoting an empty parameter indicating that no member name was specified, so sequential files are now fully supported again. (The original version of the product would have worked with sequential files as well, as the most of the logic would have used default assumptions if the parameters were not parsed correctly, but when national language support was added the code used the relevant parameter without further validation, resulting in an error when the empty member name parameter was incorrectly skipped).
Temporary fix
Comments
APAR Information
APAR number
PI08062
Reported component name
CCCA FOR OS/390
Reported component ID
5648B0500
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-12-16
Closed date
2014-07-24
Last modified date
2014-08-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI19930
Modules/Macros
ABJKCNTL ABJVCNTL
Fix information
Fixed component name
CCCA FOR OS/390
Fixed component ID
5648B0500
Applicable component levels
R210 PSY UI19930
UP14/07/25 P F407
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
04 August 2014